  • Collected exhaust

    Collected exhaust

    Exhaust manifolds are installed around the radial exhaust of pneumatic motors in ranges 10, 20, 25 and 30 (Motors from other ranges are collected by default). This allows for the collection of the engine exhaust towards a muffler, a filter, or simply to redirect it away from the workplace using a pipe.

    The use of an exhaust manifold can have an impact on the engine power. It can slightly reduce it (gamme 30) or, on the contrary, significantly increase it (gammes 10 et 20). The use of the exhaust manifold increases the maximum diameter of the engine.

    Exhaust manifolds can also be assembled on engines after manufacturing.

    Specifications

    ReferenceAC340AC341AC342AC343
    Diameter (mm)87103120130
    Connection
    Serie
    10
    20
    25
    30
  • Atex certificat

    Atex certificat

    Atex certificat

    ATEX certificate is an essential safety standard for equipment and systems used in potentially explosive environments. This certification ensures that the products meet strict standards for safety and explosion prevention.

    • Ex II 2 - G D
    • Ex h IIC T6 .. T4 - Gb
    • Ex h IIIC T80 °C .. T135 °C - Db

    Their explosion-proof nature has been certified by LCIE Bureau Veritas.

    ATEX zone is a mixture of air and flammable substances that can explode in the presence of a source of heat.

    MODEC pneumatic motors help eliminate the source of heat and thus break this triangle, ensuring the safety of people and property.

    SeriesAmbiant temperature (°C)Gaz temperature classDust temperature (°C)
    05
    07
    08
    10
    -20 °C ≤ T° ≤ 40 °CT6T80°C
    -20 °C ≤ T° ≤ 55 °CT6T80°C
    -20 °C ≤ T° ≤ 80 °CT5T95°C
    20
    25
    30
    -20 °C ≤ T° ≤ 40 °CT6T80°C
    -20 °C ≤ T° ≤ 55 °CT5T95°C
    -20 °C ≤ T° ≤ 80 °CT4T135°C
  • right/left inverser

    right/left inverser

    This option is only available on reversible pneumatic motors.

    The left/right inverter allows for controlling the change of rotation direction directly on the motor using a simple left/right lever (see photo), without the need for pneumatic assembly (5/3 distributor, multiple supply hoses).

    This option is particularly interesting for motors installed in equipment that requires manual control. The Left/Right inverter option impacts the motor's performance and provides it with the same performance as its version N (with handel) RV (reversible).

  • Lubrication free

    Lubrication free

    Lubrication free

    We offer as an option "oil-free" motors designed for applications that do not allow the use of oil.

    These motors have special bearings and stators designed for this type of operation. The speed of an "oil-free" motor is generally 5 to 15% compared to that of the same lubricated version of the motor.

    Additionally, the following precautions should be taken :

    • Maintenance must be more frequent (see table below).
    • If a non-lubricated motor is used with lubrication, it will then be necessary to continue lubricating it or dismantle it, change the vanes, and clean it entirely before using it again without oil.
    • The oil-free motor is particularly sensitive to impurities in the supply air (make sure to use clean and dry air).
    • These motors should not be operated at no-load and at full speed.
    ReferenceStandard motorLubrication free motor
    Lubrification 4,4 gouttes / N.mSpeed : 100%
    Maintenance every 1000 to 3000 hours
    Speed : 100%
    Maintenance every 1000 to 3000 hours
    Pas de lubrificationSpeed < 50%
    Maintenance every 30 to 50h
    Speed : 85%
    Maintenance every 500 to 1000h
    Type de moteurLubrification 4,4 gouttes / N.mPas de lubrification

    Standard motor
    Speed : 100%
    Maintenance every 1000 to 3000 hours
    Speed < 50%
    Maintenance every 30 to 50h
    Lubrication free motorSpeed : 100%
    Maintenance every 1000 to 3000 hours
    Speed : 85%
    Maintenance every 500 to 1000h
    ReferenceLubrication 4.4 (Nl/min)Without lubrication
    Standard motor

    Speed : 100%
    Maintenance every 1000 to 3000 hours

    Speed < 50%
    Maintenance every 30 to 50h

    Lubrication free motor

    Speed : 100%
    Maintenance every 1000 to 3000 hours

    Speed : 85%
    Maintenance every 500 to 1000h

  • Kit start

    Kit start

    Kit start

    This option is recommended for use with long periods of inactivity to ensure an immediate restart of the motor.

    The Kit start ensures that the vanes remain in position within the stator and are ready to operate as soon as the motor is powered again.

  • Integrated speed control

    Integrated speed control

    Integrated speed control

    The speed controller integrated into the pneumatic motors allows the user to control the motor's rotation speed simply by turning the silencer ring.

    No need for flow restrictors at the inlet or outlet of the motor with this compact and clever system.

  • Stainless steel motor

    Stainless steel motor

    Stainless steel motor

    Available on most of our models, this option further enhances the durability of our motors in humid or corrosive environments.

Icône emplacement
ZI Sirius Quatre
80, allée René Higonnet
26760 Beaumont-lès-Valence, FRANCE
Icône emplacement
185 Alewife Brook Parkway #210
Cambridge, MA 02138
UNITED STATES
Icône emplacement
11111 Katy Freeway suite 910
Houston, TX 77079
UNITED STATES
modec - Copyright © 2023 - All rights reserved - Made by ARKOD
crossmenu